SOFAR 3k~7.5kTL-G2 SOLAR INVERTER
3300/4400/5000/5500/6600/8800/11000/12000
Single-Phase Dual-MPPT
Built-in Zero Export Function
2 MPPT High Precision String Detection
IP65 Ingress Protection
I-V Curve Scanning Function
Max. Efficiency Up to 98.2%
Built-In Sound And Light Alarm Function
Smart Monitoring, RS485, WIFI / Ethernet / GPRS (Optional)
| Datasheet | SOFAR 3KTLM-G2 |
SOFAR 3.6KTLM- |
SOFAR 4KTLM-G2 |
SOFAR 4.6KTLM-G2 |
SOFAR 5KTLM-G2 |
SOFAR 6KTLM-G2 |
SOFAR 7.5KTLM |
| Input (DC) | |||||||
| Recommended Max. PV input power | 3990Wp | 4790Wp | 5320Wp | 6120Wp | 6650Wp | 7980Wp | 9980Wp |
| Max DC power for single MPPT | 3500W | 3500W | 3500W | 3500W | 3500W | 3500W | 2*2750W/ 2750W |
| Number of MPP trackers | 2 | ||||||
| Number of DC inputs | 1/1 | 2/1 | |||||
| Max. Input voltage | 600V | ||||||
| Start-up voltage | 120V | ||||||
| Rated input voltage | 360V | ||||||
| MPPT operating voltage range | 90-580V | ||||||
| Full power MPPT voltage range | 160V-520V | 180V-520V | 200V-520V | 230V-520V | 250V-520V | 300V-520V | 250V-520V |
| Full power MPPT voltage range | 11A/11A | 22A/11A | |||||
| Output (AC) | |||||||
| Rated power | 3000W | 3680W | 4000W | 4600W | 5000W | 6000W | 7500W |
| Max. AC power | 3000VA | 3680VA | 4000VA | 4600VA | 5000VA | 6000VA | 7500VA |
| Max. Output current | 13.7A | 16.8A | 18.2A | 21A | 22.8A | 27.3A | 32.6A |
| Nominal grid voltage | L/N/PE, 220Vac, 230Vac, 240Vac | ||||||
| Grid voltage range | 180Vac-276Vac (According to local standard) | ||||||
| Nominal frequency | 50Hz/60Hz | ||||||
| Grid frequency range | 45Hz-55Hz/54Hz-66Hz (According to local standard) | ||||||
| Active power adjustable range | 0~100% | ||||||
| THDi | <3% | ||||||
| Power factor | 1default (adjustable+/-0. 8) | ||||||
| Power limit export | Zero export or adjustable power limit export | ||||||
| Performance | |||||||
| Max efficiency | 98.0% | ||||||
| European weighted efficiency | 97.5% | ||||||
| Self-consumption at night | <1W | ||||||
| MPPT efficiency | >99.9% | ||||||
| Protection | |||||||
| DC reverse polarity protection | Yes | ||||||
| DC switch | Optional | ||||||
| Protection class/overvoltage category | I/III | ||||||
| Safety protection | Anti islanding, RCMU, Ground fault monitoring | ||||||
| SPD | MOV: Type III standard | ||||||
| Communication | |||||||
| Power management unit | According to certification and request | ||||||
| Standard communication mode | Rs485, Wifi/Ethernet/GPRS(optional), SD card(optional) | ||||||
| Operation data storage | 25 years | ||||||
| General Data | |||||||
| Ambient temperature range | -25℃~+60℃ | -30℃~+60℃ | |||||
| Topology | Transformerless | ||||||
| Degree of protection | IP65 | ||||||
| Allowable relative humidity range | 0~100% | ||||||
| Max. Operating altitude | 2000m | ||||||
| Noise | <25dB | ||||||
| Weight | 11.5kg | 18kg | |||||
| Cooling | Natural | ||||||
| Dimension | 405*315*135mm | 467*352*157mm | |||||
| Display | LCD display | ||||||
| Warranty | 5 years/ 7 years/ 10 years | ||||||
| Standard | |||||||
| EMC | EN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12 | ||||||
| Safety standards | IEC62109-1/2, IEC62116, IEC61727, IEC-61683, IEC60068(1,2,14,30) | ||||||
| Grid standards | AS/NZS 4777, VDE V 0124-100, V 0126-1-1, VDE-AR-N 4105, CEI 0-21, EN50549, G83/G59/G98/G99, NB/T32004; ABNT NBR 16149/16150 (for SOFAR3KTLM-G2, SOFAR5KTLM-G2& 7.5KTLM) |
||||||